Search

Item Details

TRIPP LITE 5-15/20R 16 Outlet 20 A 100 - 127 V Metered Power Distribution Unit

Item: IM1L81872   Model: PDUMH20AT
$442.89 Each

Pickup today

,

Out of stock online

Pickup today

,

Check another store

Pickup today

,

Check another store

Available online only

Buy in store today

,

Check another store

Out of stock online

Buy in store today

,

Check another store

Available in-store only

Free Shipping

  • Single phase NEMA 5-20P / NEMA L5-20P 12 ft 20 A 100 - 127 V input
  • 120 V 60 Hz output
  • 16 NEMA 5-15/20R outlet connector

TRIPP LITE 5-15/20R 16 Outlet 20 A 100 - 127 V Metered Power Distribution Unit provides redundant power option for critical networking equipment with a single input power cord.

TRIPP LITE 5-15/20R 16 Outlet 20 A 100 - 127 V Metered Power Distribution Unit provides a redundant power option for single-corded network devices. The dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. It enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. The ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. The front input LED's display primary or secondary power availability.

  • Single phase NEMA 5-20P / NEMA L5-20P 12 ft 20 A 100 - 127 V input
  • 120 V 60 Hz output
  • 16 NEMA 5-15/20R outlet connector
  • 1U horizontal rack mount form factor
  • Package includes PDU with attached L5-20P primary input cord, detachable C19 to NEMA L5-20P secondary input cord, set of two L5-20R to 5-20P plug adapters, 1U mounting brackets, user manual with warranty information
  • 2 digit display reports output power consumption in amps
  • Super-fast switchover between primary and secondary power sources occurs in 2-7 milliseconds
  • Front panel LEDs confirm power availability on both input lines
  • Typical applications: Ideal means to provide single-corded network gear a redundant power option
  • ATS circuits normally maintain output sourced from the primary input cable, as primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
  • ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)
  • Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
  • On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
  • Outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup
  • Indicator type: 16 front panel LEDs display power on - off status for each outlet, plus 2 LEDs for power status on each input line cord, digital current meter display shows total load consumption of connected equipment in amps
  • Certifications: Tested to UL 60950 (USA, Canada), Class A (Emissions), NOM (Mexico), RoHS complaint
  • 12.2 lbs
  • 1.75"(H) x 17.5"(W) x 4.5"(W)
  • 2 years limited warranty

Power Distribution Unit TypeMetered

Height in Inches1.75

Depth in Inches14.5

Width in Inches17.5

Product Color FamilyBlack

Cable Length (ft.)12

Load Capacity2400 VA

The product was not found. Please verify the sku and try again.